Find your starting point for solar and storage
Share your monthly electricity spend or usage, your area and your preferred solar contribution target. We’ll help match a proposed Sigenergy SigenStor Neo package to your property, then verify it against your supply phase, roof and usage patterns.
Three proposed package options
- 6kW single-phase: 4.96 kWp PV and 12.04 kWh battery configuration.
- 10kW single-phase: 8.68 kWp PV and 18.06 kWh battery configuration.
- 15kW three-phase: 12.40 kWp PV and 24.08 kWh battery configuration.
All packages are awaiting supplier costings and final equipment confirmation. Price on request; no online checkout is available for these packages.
Tailor your quotation
- Installation and COC, with installer qualifications and requested AREP / SAPVIA Solar Green Card credentials checked before appointment.
- Compatible EV charging and generator integration, subject to site assessment.
- Optional BAT 8.0 battery upgrades, subject to supplier compatibility confirmation.
Speak to our team
Request a quote on WhatsApp or email Energy of Africa. Ask for a package quote, custom design and yield report, or finance information. Finance is subject to availability and provider terms.
Package capacities are proposed configurations, not guaranteed energy independence. Final sizing requires site verification and an engineering review.
System Design Logic
Our planning model starts with 24-hour consumption split 50% day / 50% night. The PV requirement targets the full daily energy goal at an 80% performance ratio: target daily kWh ÷ (regional peak-sun-hours × 0.80). Daytime production supplies loads and charges batteries for later use.
Zero export is a proposed control strategy, subject to compatible metering, commissioning and site verification. The savings scenario assumes 90% of generated energy offsets purchased electricity; the remaining 10% is not credited. This is not guaranteed self-sufficiency: usable storage, conversion losses, seasonal weather and load timing must be checked.
Where compatible controls and daytime demand exist, surplus solar can heat a geyser or charge an EV, acting as useful additional energy storage. This does not create extra PV generation, and its benefit must not be counted twice.
Generation, Storage & Savings by Area
Illustrative merchant-supplied tariff and solar-resource assumptions, not verified current municipal tariffs or measured yield forecasts. Daily generation = PV kWp × PSH × 80%. Monthly figures use 30 days; annual savings use 365 days, so annual savings are not exactly 12 times the 30-day figure. Savings = generation × 90% × tariff, before maintenance, finance or replacement costs. Fixed charges and export revenue are excluded. Actual avoided energy is limited by consumption and storage.
| Area | Inverter / PV / proposed battery | R/kWh | PSH | kWh/day | kWh/30 days | Savings/30 days | Savings/year |
|---|---|---|---|---|---|---|---|
| Pretoria / City of Tshwane | 6kW / 4.96 kWp / 12.04 kWh | 4.20 | 5.40 | 21,43 | 642,82 | R2 429,84 | R29 563,11 |
| Pretoria / City of Tshwane | 10kW / 8.68 kWp / 18.06 kWh | 4.20 | 5.40 | 37,50 | 1 124,93 | R4 252,23 | R51 735,44 |
| Pretoria / City of Tshwane | 15kW / 12.40 kWp / 24.08 kWh | 4.20 | 5.40 | 53,57 | 1 607,04 | R6 074,61 | R73 907,77 |
| Johannesburg / City Power | 6kW / 4.96 kWp / 12.04 kWh | 4.35 | 5.40 | 21,43 | 642,82 | R2 516,62 | R30 618,93 |
| Johannesburg / City Power | 10kW / 8.68 kWp / 18.06 kWh | 4.35 | 5.40 | 37,50 | 1 124,93 | R4 404,09 | R53 583,13 |
| Johannesburg / City Power | 15kW / 12.40 kWp / 24.08 kWh | 4.35 | 5.40 | 53,57 | 1 607,04 | R6 291,56 | R76 547,33 |
| George Municipality | 6kW / 4.96 kWp / 12.04 kWh | 3.95 | 4.90 | 19,44 | 583,30 | R2 073,62 | R25 229,01 |
| George Municipality | 10kW / 8.68 kWp / 18.06 kWh | 3.95 | 4.90 | 34,03 | 1 020,77 | R3 628,83 | R44 150,77 |
| George Municipality | 15kW / 12.40 kWp / 24.08 kWh | 3.95 | 4.90 | 48,61 | 1 458,24 | R5 184,04 | R63 072,53 |
| SA National Baseline | 6kW / 4.96 kWp / 12.04 kWh | 4.17 | 5.00 | 19,84 | 595,20 | R2 233,79 | R27 177,72 |
| SA National Baseline | 10kW / 8.68 kWp / 18.06 kWh | 4.17 | 5.00 | 34,72 | 1 041,60 | R3 909,12 | R47 561,02 |
| SA National Baseline | 15kW / 12.40 kWp / 24.08 kWh | 4.17 | 5.00 | 49,60 | 1 488,00 | R5 584,46 | R67 944,31 |
Battery figures are the proposed package capacities, not confirmed usable energy. Optional BAT 8.0 upgrades require supplier confirmation of compatibility and usable capacity; additional batteries do not increase PV yield and only increase savings where otherwise-unused solar can replace grid energy.
Payback Period (Base Package + 15% Installation)
Simple payback in years = (base package cost × 1.15) ÷ estimated annual savings. The 15% installation allowance is illustrative, not a fixed installation quotation. Base cost benchmark = (PV kWp × 1,000 × selected R/W benchmark) + (battery kWh × selected R/kWh benchmark). These rates must include the intended inverter, mounting and protection scope or those costs must be added separately; do not double-count items already included. Use a consistent VAT basis.
Pricing is pending final supplier confirmation. No numerical payback is shown until cost inputs are supplied. This static explanation does not change the interactive calculator's settings. If annual savings are zero or negative there is no positive simple payback. Simple payback excludes escalation, financing, maintenance and replacements; it is not a guaranteed investment return.
Heavy Loads Guide
Appliance count alone cannot determine support: read each appliance’s rated demand, allow for the rest of the property, startup surges, battery discharge limits and phase limits. For illustration only, assume each geyser, oven or aircon draws 3kW while running, plus a separate 1kW essentials allowance. Actual appliances may draw substantially more or less.
- 6kW single-phase: One illustrative 3kW heavy load plus 1kW essentials totals 4kW. Two such loads plus essentials total 7kW, so stagger them on backup.
- 10kW single-phase: Two illustrative 3kW heavy loads plus essentials total 7kW. Three plus essentials total 10kW, leaving no margin, so stagger rather than treating this as a safe operating recommendation.
- 15kW three-phase: Up to three illustrative 3kW loads plus essentials total 10kW in aggregate, only if phase allocation, inverter phase limits, surge and battery discharge capability permit. Four total 13kW but may still exceed an individual phase limit; engineering verification is essential.
For example, a geyser, oven and aircon operated together count as three loads in this illustration; they are not automatically supported simply because the inverter total appears sufficient. Schedule geysers, cooking and EV charging at different times to reduce simultaneous demand.
Grid pass-through: A requested 63A pass-through specification remains unverified for the final inverter/gateway combination. Pass-through is not extra inverter or battery backup output and is unavailable when grid supply is absent; applicable per-phase and installation limits require confirmation.
EV charging: 7.4kW single-phase and 22kW three-phase are proposed charger options, not confirmed included capabilities. At full output they exceed the respective 6kW and 15kW inverter ratings; use suitable grid-assisted operation or compatible current limiting/load management. The 10kW package also needs careful allowance for other loads. Vehicle, charger, supply, per-phase limits and installation compatibility must be verified.